Ultra Inert (UI) Columns have consistent inertness performance from column to column

Ultra Inert (UI) GC Columns push industry standards for consistent column inertness in a variety of stationary phase polarities. Gas Chromatography (GC) column inertness is critical, as columns contribute toward the largest surface area within an inert flow path. As samples become increasingly active and more complex, you cannot afford interferences introduced by the analytical flow path, such as GC columns, liners, septa. 

AGilent Ultra Inert (UI) GC Columns
Request Info/Quote

Ultra Inert (UI) GC Columns

DB-624 Ultra Inert Columns

DB-624 Ultra Inert (UI) column is optimal for the fast & accurate analysis of volatile organic compounds (VOCs) in pharmaceutical, environmental, food, and industrial chemical applications by GC and GC/MS. Following from its predecessor, this Ultra Inert version of the industry standard DB-624 is also a mid-polar 6% cyanopropyl/phenyl, 94% polydimethylsiloxane, equivalent to USP phase G43. The unique Ultra Inert deactivation process was developed to enhance peak shape for active volatile compounds, improving signal-to-noise levels and increasing sensitivity for qualitative and quantitative analysis of complex VOC mixtures.

Features

  • Environmental volatile organic compounds (VOCs) methods
  • Excellent for US EPA Methods: 501.3, 502.2, 503.1, 524.2, 601, 602, 8010, 8015, 8020, 8240, and 8260
  • Ideal for PFAS testing in air sampling
  • Industrial chemical analysis – solvents, petrochemicals, specialty chemicals
  • Food and beverage – alcohol, fusel oils
  • Pharmaceutical residual solvents per USP
  • Ultra inertness processing expands application range with excellent peak shape for low molecular weight acidic compounds
  • UI testing ensures premium performance column-to-column
  • Identical selectivity to the industry standard DB-624 – upgrade with no change in method required
  • Optimized by the inventors of DB-624
Request Info/Quote

Intuvo Ultra Inert Columns

As part of the Agilent J&W Ultra Inert GC column family, Ultra Inert Intuvo GC columns (compatible only with the Intuvo 9000 GC System) push industry standards for consistent column inertness and exceptionally low column bleed, resulting in lower detection limits and more accurate data for difficult analytes.

Offered in a wide range of stationary phase polarities (non, low, mid, and high polarity), each Ultra Inert Intuvo GC column is tested with the industry’s most demanding test probe mixture, and a performance summary sheet is shipped with each column.

Features

  • Wide selection of stationary phase polarities are available (non, low, mid, and high polarity)
  • Strict quality control specifications and testing ensure long-term column-to-column performance and accurate separations
  • Optimized GC flow path with Agilent Ultra Inert Liners, low-bleed septa, certified vials, and gas clean filters
  • For use with the Agilent Intuvo 9000 GC System
Request Info/Quote

DB-5ms Ultra Inert Columns

Agilent J&W DB-5ms Ultra Inert columns deliver industry-leading analytical performance in a range of chromatographic applications. DB-5ms Ultra Inert is low bleed and features excellent signal-to-noise ratio and symmetric peak shapes, enabling high performance for challenging active analytes such as pesticides, dioxins, PCBs, and other challenging semi-volatile compounds. DB-5ms Ultra Inert is tested with a demanding test probe mixture to ensure consistent column inertness.

Features

  • Individually tested with Über One test probe mixture
  • Consistent column inertness performance
  • Exceptionally low column bleed
  • Great peak shapes for challenging active analytes such as pesticides and drugs of abuse
  • Excellent signal-to-noise ratios
  • Minimum compound adsorption or degradation
  • Support of 0.18 mm id column configuration for higher sample throughput
  • Tested with the tightest industry Quality Control (QC) specifications for column bleed, sensitivity, and efficiency
  • Performance Summary shipped with each column
Request Info/Quote

HP-5ms Ultra Inert Columns

Agilent J&W HP-5ms Ultra Inert is a (5%-phenyl)-methylpolysiloxane specifically tested for inertness in the analysis of active compounds, including acidic and basic compounds, to meet the growing need for lower detection levels. With very low bleed characteristics, this bonded and crosslinked column is solvent rinsable and ideal for GC/MS. It is equivalent to USP phase G27 and features improved signal-to-noise ratio for better sensitivity and mass spectral integrity.

Features

  • Excellent for trace-level analysis of acids and bases
  • (5%-Phenyl)-methylpolysiloxane has identical selectivity to HP-5MS
  • Specifically tested for inertness for active compounds, including acidic and basic compounds
  • Improved signal-to-noise ratio for better sensitivity and mass spectral integrity
  • Nonpolar with very low bleed characteristics, ideal for GC/MS
  • Bonded, crosslinked, and solvent rinsable
  • Equivalent to USP phase G27
  • Tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency
  • Performance Summary shipped with each column
  • Similar phases: Rtx-5ms, Rxi-5ms, Rxi-5Sil MS, PTE-5, BPX-5, AT-5ms, ZB-5ms, ZB-5ms Plus, SLB-5ms, Equity-7
Request Info/Quote

DB-WAX Ultra Inert GC Columns

Gas chromatography (GC) columns with polyethylene glycol (PEG) stationary phases, also known as WAX GC columns, are commonly used for analyzing compounds with polar functional groups. They are well suited for food, flavor, and fragrance applications, as well as industrial chemical analysis in quality control (QC) and method development labs.

DB-WAX Ultra Inert (UI) represents the ultimate performance of PEG stationary phase inertness, providing symmetric peak shape and improved response for challenging polar compounds. All DB-WAX UI columns are individually tested with an Ultra Inert Wax test probe mixture according to the strictest industry QC standards to ensure consistent column-to-column inertness performance for challenging active analytes, such as free fatty acids, alcohols, diols, and aldehydes, with minimal compound adsorption or degradation.

Since it offers the same selectivity as Agilent J&W DB-WAX, upgrading to Ultra Inert performance is easy, with minimal validation required. There is no need to recreate or modify existing compound libraries that are based on DB-WAX selectivity.

Features

  • Improved peakshape for challenging polar compounds with DB-WAX Ultra Inert
  • Reliable column-to-column inertness performance
  • Bonded polyethylene glycol (PEG) selectivity equivalent to DB-WAX
  • Save time since no method revalidation needed
  • High polarity
  • Equivalent to USP G16
  • Excellent performance for acidic compounds, including free fatty acids – no need for FFAP type column
  • Bonded and crosslinked phase is solvent rinseable and tolerates aqueous injections
Request Info/Quote

DB-35ms Ultra Inert Columns

Agilent J&W DB-35ms Ultra Inert is a mid-polarity column for applications where different selectivity is needed for enhanced separations, including pesticide analysis and drugs of abuse testing. This column quantifies components at a lower level, with broader linearity and optimized separation, ultimately increasing productivity.

Features

  • Individually tested with the Ultra Inert DB-35ms test probe mixture
  • Consistent column inertness performance
  • Exceptionally low column bleed
  • Great peak shapes for challenging active analytes, with excellent signal-to-noise ratios
  • Minimum compound adsorption or degradation
  • Supports 0.18 mm id column configuration for higher sample throughput
  • Tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency
  • Performance Summary shipped with each column

DB-Select 624 UI 467 Columns

J&W DB-Select 624 UI 467 GC columns are designed specifically for United States Pharmacopoeia Method 467. Equivalent to USP phase G43, this stationary phase is engineered for the best sensitivity and resolution of the critical pairs specified in 467 for the analysis of residual solvents in active pharmaceutical ingredients (APIs).

Features

  • Engineered to optimize pharmaceutical residual solvents analysis per USP Method <467>
  • Ultra inertness and low bleed
  • Resolution of USP regulated critical pairs, also separates benzene and 1,2-dichloroethane
  • Identical selectivity to the popular VF-624 ms – upgrade with no changes in method
  • UI testing ensures premium performance column to column
  • Tested against the strictest industry QC specifications for column bleed, sensitivity and efficiency
  • Performance Summary shipped with each column
Request Info/Quote

DB-1ms Ultra Inert Columns

Agilent J&W DB-1ms Ultra Inert delivers consistent column inertness performance to ensure analytical sensitivity and integrity. With excellent peak shapes, exceptionally low bleed, and high signal-to-noise ratios, this column performs effectively with even the most challenging active analytes.

Each column is individually tested with Ultra Inert 1ms test probe mixture.

Features

  • Individually tested with Ultra Inert 1ms test probe mixture
  • Consistent column inertness performance and exceptionally low bleed
  • High-quality peak shapes for challenging active analytes
  • Excellent signal-to-noise ratios
  • Minimum compound adsorption or degradation
  • Supports 0.18 mm id column configuration for higher sample throughput
  • Tested against the strictest industry QC specifications for column bleed, sensitivity and efficiency
  • Performance Summary shipped with each column
Request Info/Quote

HP-1ms Ultra Inert Columns

Agilent J&W HP-1ms Ultra Inert features exceptionally low column bleed and is designed to deliver consistent column inertness performance. They are individually tested with an Ultra Inert 1ms test probe mixture according to the strictest industry QC standards to ensure excellent signal-to-noise ratios and high-quality peak shapes for challenging active analytes.

These columns deliver high levels of accuracy and results integrity in a range of applications, with minimal compound adsorption or degradation.

Features

  • Individually tested with Ultra Inert 1ms test probe mixture
  • Consistent column inertness performance
  • Exceptionally low column bleed
  • Great peak shapes for challenging active analytes
  • Excellent signal-to-noise ratios
  • Minimum compound adsorption or degradation
  • Supports 0.18 mm id column configuration for higher sample throughput
  • Tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency
  • Performance Summary shipped with each column
Request Info/Quote

DB-UI 8270D Ultra Inert GC Columns

J&W DB-UI 8270D Ultra Inert GC Columns deliver excellent peak shape for trace-level analysis of active semi-volatile organic compounds targeted by EPA method 8270D. Leading-edge manufacturing processes, combined with optimized chemistries and design advancements, improve both inertness and column-to-column reproducibility with no trade-offs in bleed or stationary phase selectivity.

All DB-UI8270D Ultra Inert columns are individually tested with the most highly probative semi-volatile compounds, including propanoic acid, pyridine, 1,2 butanediol, 1-chloro-2-fluorobenzene, and m/p xylene, at low temperature (45 °C), to ensure excellent peak shape performance at low levels (5 to 10 ng on-column).

Features

  • Specifically engineered for improved trace-level analysis of active semivolatile organic compounds
  • Industry-leading Ultra Inert deactivation and manufacturing
  • Unmatched testing protocol provides ultimate confidence in your results
  • “MS-Grade” low-bleed stationary phase ensures the lowest interference from the column at elevated temperatures
  • Tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency
  • Performance Summary shipped with each column
Request Info/Quote