Benefits of Agilent Cary 60 Double Beam UV-Vis

The Cary 60 UV-Vis spectrophotometer has a wavelength range of 190–1100 nm that can be scanned in under three seconds. Our flexible UV-Vis spectrophotometer can be fitted with long pathlength cuvettes and solid sample transmission or reflectance accessories and is ideal for remote UV-Vis absorbance analysis, when fitted with fiber optic probes.

Cary 60 Double Beam UV-Vis
Request Info/Quote

Benefits

  • UV-Vis Spectrophotometer designed based on double beam, Czerny-Turner monochromator, 190–1100 nm wavelength range, full spectrum Xenon pulse lamp single source with exceptionally long life, dual silicon diode detectors, quartz overcoated optics, scan rates up to 24,000 nm/min, 80 data points/sec maximum measurement rate, non-measurement phase stepping wavelength drive, room light immunity, central control by PC, Supported by GLP software, optional 21 CFR Part 11 capable software, and dedicated instrument validation software which includes pharmacopeia test suites.
  • Source: Xenon Pulsed lamp cover complete UV-Vis range and with very long lifetime up to 10 years.
  • Room light immunity: Unique optical design allows accurate sample measurement even with the sample lid open — especially useful for enzyme assays, fiber-optic based measurements or high throughput QA/QC labs.
  • Photometric range up to 4 Abs: Permits the analysis of highly turbid solutions and a wide range of sample concentrations (optical densities), as well as reducing sample preparation (dilution) requirements.
  • Non-measurement phase stepping wavelength drive: Means that sample and reference measurements are made at the same wavelength ensuring that no peak shifts are observed — even when measuring at the
  • fastest scan speeds.
  • Focused Beam: allows the instrument to measure low sample volume µL and to work as nanodrops with hellma tray cell.
  • 24,000 nm/min maximum scan rate: Allows complete spectral range scanning in under 3 seconds, ideal for
  • fast kinetics or high sample throughput.
  • Detectors: 2 silicon diode detectors for simultaneous sample beam and reference beam measurements
  • Data collection rate: 80 data points/second
  • Temperature monitor: Temperature probe inside cuvette (using the Temperature Probe Accessory).
  • Instrument dimensions (width x depth x height): 477 x 567 x 196 mm (19 x 23 x 8 in)
  • Instrument weight: 18 kg (40 lb)
  • Baseline flatness: 200 to 850 nm, baseline corrected 0.0004 Abs
  • Compartment size (width x depth x height): 130 x 523 x 123 mm (5.2 x 20.6 x 4.8 in)
  • Note that sample compartment can be left open during measurement due to room light immunity of Cary 60.
  • Availability to use 18 cell holder with temperature control.
  • Ability to use as portable instrument.